Posts Tagged ‘decap ic fuse bits’

PostHeaderIcon PIC16C55 EEPROM: Why a Wide Die Is Opened for a Probe

Opening a package is a means, and on the PIC16C55 the end is usually electrical rather than optical. The part carries the same 512 words of twelve-bit program memory as its smaller relative, but it puts them on a die sized for 28 pins, and the extra area is mostly room: room for bond pads, room for bus routing, room to land a probe without touching anything that matters.

Decap IC PIC16C55 Eeprom and extract mcu pic16c55 heximal from flash memory, and clone firmware to new microcontroller pic16c55 to provide the same functions

A wide die is mostly periphery

Port expansion is not free in silicon, but it is cheap in area at this process node. The array stays the same size while the pad ring and the I/O logic grow, so a part built for 28 pins has generous spacing between the array and the edge. Every one of those pins has a driver, and every driver is fed by a bus that has to come from somewhere. When the array is protected, those buses are the next best thing to the array itself, because they carry what the array contains.

Why a probe beats a microscope here

An optical read is a per-cell measurement: one image per block, one classification per cell, and a stitching exercise afterwards. A probe read is a bus transaction: address on one set of lines, data on another, clock it and capture. On a die this size the pads are large enough to land on with a mechanical probe station, and the address and data paths are wide and slow by later standards, which means a capture does not need heroic timing. The result is the image with far less interpretation and a correspondingly smaller chance of a bit error.

The lines worth finding

Signal group Where it lives Why it helps
Program address Between PC logic and array Tells you where the read is
Program data Array output latches The word itself
Instruction clock Near the oscillator block Gives you a capture trigger
Reset and MCLR Edge of the pad ring Repeatable start point

The third row is the one that makes the work practical. Without a stable trigger the capture is a guess about alignment; with the instruction clock brought out to a pad, every fetch has a known boundary and the data lines can be sampled in the middle of their valid window.

Decap for a probe is not decap for a photo

The two jobs want different things from the opening. A photographic read wants the array clean, flat and free of any residue that would scatter light, which pushes towards a wide opening and a careful final clean. A probe read wants the bond pads exposed and the surface mechanically stable enough to take a touchdown, which pushes towards a narrower opening that leaves the passivation over the array intact. Doing both in one pass is possible and is usually a compromise: the pads get contaminated by the etch, or the array gets scratched by the probe.

The risks that decide the schedule

Mechanical contact is the obvious one and the least common. More often the damage is chemical: an etch that runs a few seconds long undercuts the passivation near the pad ring and lifts the metal that the probe is supposed to land on. The second risk is static, which on a part of this age is a real failure mode and not a formality. Both are reasons to open a spare unit first when one exists, and to accept that a single-unit job has no rehearsal.

The read that comes after

A probe capture is not a file. It is a stream sampled off the bus, with the alignment decided by the trigger and the word boundary decided by the address lines, and it has to be reconciled against the memory map before anyone calls it a program. The reconciliation is cheap: if the capture is right, the words disassemble into an instruction stream that runs to the reset vector and back. If it is wrong, the disassembly shows the same instruction repeating at a period equal to the misalignment, which is a distinctive failure and an easy one to correct.

When this is the right call

It is the right call when the array is protected, the die is large, and the customer needs a bit-exact image rather than a functional rebuild. It is the wrong call when the protection is clear, because a pin-level read costs minutes, and it is the wrong call when the part is a plastic OTP with the same die as an 18-pin sibling, where the smaller die is cheaper to work. The comparison to the 54A is in decap of the 54A and the smaller package variant in PIC16C58B; the technique itself belongs to the wider family described in attacking an MCU.